Model NO.
GYTC8S
Material Shape
Round Wire
Allowed Lateral Pressure
>1000(N/100mm)
Allowed Tensile Strength
1000N<10000N
Core
Double Core
Certification
RoHS, CE, ISO9001
Brand
Hanli
Sheath Material
Crosslinking
Model No
Central Loose Tube GYTC8S Fiber Optic Cable
Packing
Wooden Drum
Weight
100kg
Fiber Type
G652D
Transport Package
1000/2000/3000m
Specification
4-48 C
Trademark
HANXIN
Origin
Zhejiang
HS Code
8544700000
Production Capacity
2000000m/Month
Packaging & Delivery
Package Size
100.00cm * 100.00cm * 90.00cm
Package Gross Weight
100.000kg
Product Description
Central Loose Tube GYTC8S Fiber Optic Cable
Application
This cable is ideal for in long distance and interoffice communication in strong current zone, as well as power transmission system. The built in suspension stranded rope provides high tensile strength, enabling the cable suited for large span installation, resulting in time and installation cost savings. The suspension wire, being an integral part of the cable, is easily available for gripping, fastening and pulling. This cable is featured of its lightness, low dispersion and high tensile strength.
Description
The cable consists of 5 to 36 fibers containing tubes or fi llers stranded in up to 3 layers around a central strength member and bound under a PE jacket. Each jelly fi lled tube contains 4 -12 fi bers. Solid or stranded steel wire coated with polyethylene is usually used as central strength member. Fiber glass reinforced plastics (FRP) will be used as central strength member if non metallic construction is required. Either aramid yarn or fi ber glass is wound around the tube to provide physical protection and tensile strength. Water blocking materials are fi lled in the interstice of the cable core, core wrapping layer/water blocking tape. The cable can be jacketed with either PE, PVC or LSZH though PE is the preferred option for water protection purpose. For direct burial, steel wire armour or corrugated steel tape armour is applied with an optional inner jacket of either PVC or PE. An optional Aluminium moisture tape can be incorporated under the jacket for water blocking and shielding purpose. Cable cores are connected with the suspension wires by PE sheath to form a fi gure "8" shape. An optional ripcord is located under the jacket to facilitate jacket removal.
Physical Properties
Fiber Count | Nominal Weight(kg/km) | Nominal Weight(lb/kft) | Nominal Outer Diameter(mm) | Nominal Outer Diameter(in) | Maximum Pulling Load | |
Installation(N/Ib) | In Service(N/Ib) | |||||
2-24 | 389.0 | 261.07 | 12.6*25.1 | 0.50*0.99 | 2670/600 | 890/200 |
36-72 | 429.0 | 287.92 | 14.7*27.1 | 0.58*1.07 | 2670/600 | 890/200 |
96-144 | 571.0 | 383.22 | 20.2*32.6 | 0.80*1.29 | 2670/600 | 890/200 |
2-24 | 303.0 | 203.36 | 9.1*21.5 | 0.36*0.85 | 2670/600 | 890/200 |
36-72 | 332.0 | 222.82 | 11.1*23.5 | 0.44*0.93 | 2670/600 | 890/200 |
96-144 | 417.0 | 279.87 | 15.9*28.3 | 0.63*1.12 | 2670/600 | 890/200 |
Physical Properties
Fiber Count | Nominal Weight(kg/km) | Nominal Weight(lb/kft) | Nominal Outer Diameter(mm) | Nominal Outer Diameter(in) | Maximum Pulling Load | |
Installation(N/Ib) | In Service(N/Ib) | |||||
2-24 | 389.0 | 261.07 | 12.6*25.1 | 0.50*0.99 | 2670/600 | 890/200 |
36-72 | 429.0 | 287.92 | 14.7*27.1 | 0.58*1.07 | 2670/600 | 890/200 |
96-144 | 571.0 | 383.22 | 20.2*32.6 | 0.80*1.29 | 2670/600 | 890/200 |
Mechanical Properties
Minimum Bending Radius: | Maximum Compressive Load: | 4000N for unarmored cables; | |
Under installation: | 20×OD | 6000N for armoured cables | |
During operation | 0×OD for unarmoured cables | Repeated Impact: | 4.4 N.m (J) |
20×OD for armoured cables | Twist (Torsion): | 180×10 times, 125×OD | |
Temperature Range: | Cyclic Flexing: | 25 cycles for armoured cables. | |
Operating Temperature Range: | -40ºC(-40ºF) to +70ºC(+158ºF) | 100 cycles for unarmoured cables. | |
Storage Temperature Range: | -50ºC(-58ºF) to +70ºC(+158ºF) | Crush Resistance: | 220N/cm (125lb/in) |
Fiber Compliance
Temperature Cycling Tensile Strength Crush Impact Repeated Bending Torsion Kink Cable Bend Cool Bend | IEC60794-1-2-F2 IEC60794-1-2-E1A IEC60794-1-2-E3 IEC60794-1-2-E4 IEC60794-1-2-E6 IEC60794-1-2-E7 IEC60794-1-2-E10 IEC60794-1-2-E11 IEC60794-1-2-E11 |
Safety Compliance
General Purpose Grade | Flammability Test: OFN (UL1581) |
Riser Grade | Flammability Test: OFNR/FT4 (UL1666) |
Plenum Grade | Flammability Test: OFNP/FT6 (UL 910) |
FRPVC Grade | Flammability Test: IEC60332-1 |
LSZH Grade | Halogen Content Test: IEC 60754-1 Acidity Test: IEC 60754; Smoke Emission Test: IEC61034-1/2 |
LSFROH Grade | Halogen Content Test: IEC 60754-1 Acidity Test: IEC 60754; Smoke Emission Test: IEC61034-1/2 Flammability Test: IEC60332-1 & IEC 60332-3C/A |
FR Grade | Fire Resistance Test : IEC 60331 / BS 6387 CW |
Welcome to visit our factory and get our samples.
Your inquiry will be answered within 24 hours .Wishing to be your long- term partner ,please feel free to contact me ,we will do our best for you.
Choose us, won't make you disappointed:
1.6years manufactory experience
2.OEM/ODM available
3.Steady product quality
4.Strict quality control
5.Strictly conform to CE,ROHS,Iso9001
6.Quick delivery time(20ft,25days
1.Can I have some samples for testing quality?
A1.Yes, you can buy some samples of any our products for testing quality and market.
2.What is delivery time if we place order?
A2. It depends on order quanities. Usually,we can deliver goods within 15 days for small order. For more QTY, Let's confirm when you place official order.
3.Do you accept OEM/ODM?
A3. We support OEM/ODM service.pls don't hesitate to tell us your details.